Skip to main content

Crossing logic

The logic defines when sounds (repetitions and intensities) are triggered and when electrical stimuli are initiated.

This logic can be updated remotely per collar based on the farmer's needs.

Events

EventDetails
Zone entry soundNo sound on buffer-zone entry
Perimeter crossing soundAs soon as the animal enters the buffer zone (1), a strong continuous warning sound starts
Perimeter crossing soundThe sound lasts 5 seconds (single sound event)
Electrical stimulus triggerIf the animal does not move back within 5 seconds of the sound, one electrical stimulus is delivered

Definitions

(1) Buffer zone: the 2-meter zone before the perimeter limit.

Electrical stimulus values: 0.5 J at 2 kV (instantaneous).

If no message is received by Datacake for more than 1 hour, an email is sent. The logic is not affected; only event transmission stops.

Email notification example

Status examples

The images below show an example perimeter (Thonon) and the collar status in Datacake during power-on and zone entry.

Status example 1

Status example 2

Status example 3